Site icon AskForney

FORNEY EASY WELD 140 FC-I QUICK START GUIDE

Forney Easy Weld 140 FC-i

Get started with the Forney Easy Weld 140 FC-i! This is a breakdown of the Quick Start Guide that is included with your new machine.


FIRST STEPS

1. Read User Manual

2. Install wire spool

a. 0.030” (0.8mm) diameter

3. Set drive roll

a. Face the side marked 0.030” away from the machine

4. Feed wire and set pressure

a. For proper tension align the tops of the screw and nut together

5. Connect to Input Power

a. Generator OK with continuous output ≥ 4,000 W

b. Extension cord: #12 AWG or larger; 25’ (8m) or shorter

6. Remove consumables and depress trigger until wire comes out. Replace consumables.

7. Adjust wire feed speed () and voltage (). See chart on welder for correct settings.

8. With contact tip 1/4″ from metal, depress trigger completely to initiate arc.

MIG Troubleshooting Tips

Both LED lights off

Both LED lights on

Aluminum welding

Workpiece grounding

Frequently tripping circuit breaker or exceeding duty cycle

Low weld output or poor fusion

Improper wire spool installation

Too much spool tension

Incorrect drive roll pressure

No arc start on contact

Mismatched drive roll, liner, or contact tip size

Exit mobile version